Skylights in a hot climate: daylight without overheating in Riyadh
A skylight can fill a stairwell with daylight or turn the room below into the hottest space in the house. In Riyadh the result depends on a few decisions: how much roof to glaze and where, which glass goes overhead, how water drains and how the glass is kept clean.
Published by Alfa Aluminium · · Updated · 9 min read

Why roof glass behaves differently in Riyadh
In a Riyadh summer the midday sun is high. A wall window meets it at a glancing angle, but a roof faces it almost head-on. The US Department of Energy's Building America Solution Center states that on a midsummer day a roof can receive roughly three to four times as much solar radiation as the same area of north- or south-facing wall.
The same source advises keeping skylight area to a minimum, considering north- or south-facing clerestory windows instead, and choosing the lowest SHGC practical for the climate. In a hot climate, the skylight often decides whether a room overheats.
Decide size and position before choosing glass
The first decision is how much roof to open and where. As a reference point, the 2015 International Energy Conservation Code generally limits skylight area in commercial buildings to no more than 3% of the gross roof area, with some exceptions. It is not a Saudi rule, but it shows how modest an effective roof light can be.
- Over circulation: stairs, corridors, entrance halls and double-height spaces, where people pass rather than sit.
- Over courtyards and atriums, where light spreads down the walls.
- Away from fixed seating: not directly above sofas, beds, desks, majlis seating or screens.
- Alternatives: clerestory windows, tubular daylighting devices (which ENERGY STAR treats as skylights), or a shaded terrace with pergolas and skylights planned together.
Fixed rooflights, linear skylights and glazed canopies suit different spaces; see our aluminium and glass skylight systems.
Choosing the glass build-up for heat and glare
A skylight over a conditioned room is normally an insulated glass unit: a coated outer pane, a sealed cavity and a laminated inner pane. SHGC, light transmission and U-value are explained in our high-performance glass guide.
As a benchmark, ENERGY STAR Version 7.0 (US EPA, effective 23 October 2023) sets an SHGC of 0.25 or lower and a U-factor of 0.50 Btu/h·ft²·°F or lower for residential skylights in all zones except the Northern one, about 2.8 W/m²K by our conversion. Your consultant confirms the values for a Saudi project.
| Layer | Its job on the roof | What to ask for |
|---|---|---|
| Outer pane | Rejects solar heat | Low-SHGC solar-control or Low-E coating, with data for the whole unit |
| Cavity and edge seal | Slows conducted heat | U-value, and whether it is stated for sloped or vertical glass |
| Inner pane | Holds together if broken | Laminated glass, interlayer stated |
| Diffusing option | Reduces glare and hot spots | Translucent interlayer or patterned glass |
VELUX Commercial explains that sloped glazing has a higher, worse U-value than the same glazing installed vertically, because the gas in the cavity circulates more; with cavities of about 10 mm or less the effect is small. CE-marked Uw values for roof windows are declared at 90 degrees, so the U-value on a data sheet may be lower than the U-value at the installed slope.
Safety overhead: why the inner pane is laminated
Glass above people must stay in place if it breaks. Laminated glass keeps its fragments on the interlayer; tempered glass breaks into small pieces that can still fall. British Standards allow toughened inner panes in some cases where the rooflight is less than 5 m above floor level, subject to a risk assessment, but the Rooflight Association and VELUX Commercial recommend laminated inner panes regardless of height or location.
The International Building Code is a useful reference. Section 2405, as adopted in the 2015 Seattle Building Code, treats glass more than 15 degrees from vertical as sloped glazing and allows laminated glass with at least a 0.76 mm PVB interlayer, wired glass, approved plastics, heat-strengthened or fully tempered glass. Heat-strengthened or fully tempered glass used as single glazing, and heat-strengthened, fully tempered or wired glass used as the bottom layer of a multi-layer unit over a walking surface, need a screen below them, apart from limited exceptions, including some for dwelling units.
- Walking on it is a separate question. Laminated roof glazing can achieve a non-fragility classification, for example CWCT Class 2 or Class B to ACR(M)001, so it can stop a person falling through even if the glass breaks. Non-fragility is measured on the whole roof assembly: the glass, the framing and how the glass is fixed. A laminated inner pane alone does not make a skylight walkable.
- Used roofs need a plan. Where people reach the roof, ask for non-fragile glass or add guarding.
- Factory skylights carry a label. IBC 2405.5 requires unit skylights and tubular devices to be tested and labelled to AAMA/WDMA/CSA 101/I.S.2/A440.
Heat inside the glass: thermal stress
Vitro explains that thermal stress breakage happens when the centre of a pane gets hotter than its edge in the frame. Tinted and spectrally selective glasses absorb solar radiation, so they are more susceptible than clear glass.
- Partial shade: Vitro advises minimising locations where less than 50% of a panel is shaded. Parapets, AC units and pergola beams cast exactly this kind of shadow.
- Interior blinds can raise the temperature of the glass.
- Heat-treated glass is Vitro's suggestion where analysis shows a higher risk.
Do not add a dark film or a blind under an existing skylight without first checking the glass with your supplier.
Slope, upstand and drainage
Rain in Riyadh is infrequent but can be heavy. A skylight has to shed water quickly and keep it away from the glass edges.
- Fall: manufacturers differ. One installation guide treats 5 degrees as the minimum to shed water and leaves the final fall to the installer; another specifies at least 3 degrees to avoid ponding marks. AAMA's design guide GDSG-1-19 advises avoiding slopes under 15 degrees unless positive drainage or weep systems are designed. The system manufacturer's requirement governs.
- Upstand: IBC 2405.4 requires skylights at less than 45 degrees from horizontal to sit at least 102 mm above the roof on a curb, with an exception for houses on roofs pitched at 14 degrees or more. The Construction Specifier reports industry guidance of typically 203 mm minimum.
- Flashing: a continuous pan flashing at the perimeter, with counterflashing over the top edge of the roofing base flashing.
- Internal drainage: water should be led away from the edges of insulated units, to avoid edge-seal failure, fogging and debonding of the laminated interlayer.
Agree in advance who is responsible for the curb, the waterproofing turn-up and the flashing.
Condensation or leak?
Condensation forms when moist indoor air meets a cooler surface. In Riyadh it mostly appears on winter nights and in humid rooms: kitchens, bathrooms, indoor pools and tall halls with still air. The Construction Specifier notes that skylights are particularly prone to it in tall spaces with little air movement and in high-humidity spaces such as indoor pools.
- Warmer glass: Natural Resources Canada lists triple glazing, Low-E coatings and gas fill as helpful. A thermal-break frame also keeps the frame's inner face warmer.
- Air movement: air flowing across the glass keeps it warmer.
- Humidity control: extract fans, pool dehumidification and integral condensate gutters.
Diagnose before replacing anything: perceived leakage is sometimes condensation, and forensic water testing such as AAMA 511 should come first. Water after rain points to a leak; water on cold dry mornings points to condensation. Mist between the panes means a failed seal.
Dust, cleaning and maintenance
A KFUPM study in Dhahran measured a 20% drop in glass transmittance on PV glass tilted at 26 degrees after 45 days outdoors. In Jeddah, dust cut a horizontal PV module's output by up to 80.4% after 183 days without rain. These are solar panels, not skylights, but they show how fast dust builds up and that flat glass is worst.
Pilkington states that its self-cleaning coating needs daylight and rain, recommends a slope of at least 10 degrees (30 degrees or more is ideal), and notes that inorganic dirt is not washed off in dry weather.
- After a dust storm, rinse with plenty of water before wiping, using soft tools.
- Before the rainy season, clear gutters, outlets and weep holes.
- Twice a year, inspect sealant and gaskets for cracks or gaps.
- From inside, look for ceiling stains and mist between panes.
- Plan safe access: do not stand or walk on roof glass; use walkways, edge protection or a cleaning platform. A non-fragile rating protects against an accidental fall, not routine foot traffic.
Briefing a skylight project in Riyadh
The Saudi Energy Conservation Code SBC 602 covers low-rise homes, and your consultant confirms the envelope values (see why insulation matters in Saudi Arabia). A supplier needs:
- A roof plan and section with the opening, slope and parapets.
- The room's use, ceiling height and humidity sources.
- Nearby equipment, pergolas or walls that may shade the glass.
- Whether people use the roof, and how the glass will be cleaned.
- The look you want: clear sky view or diffused light.
Our project at a private farm in Al Muzahmiyah, Riyadh includes a curtain wall façade, an aluminium skylight and smart aluminium doors. When you are ready, our quotation guide lists what to send.
Planning a skylight in Riyadh or elsewhere in Saudi Arabia?
Send us your roof plan, the room use and photos of the roof. The Alfa Aluminium team in Riyadh can review skylight size, glass build-up, drainage and access for your project.
Every installation carries a 5-year warranty on aluminium installation against water and dust leakage.
Discuss your skylightRelated pages
Sources
- U.S. DOE / PNNL Building America Solution Center — Shading and solar control for windows and skylights
- US EPA — ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights, Version 7.0
- IEA Policies Database — IECC 2015, International Energy Conservation Code
- City of Seattle — 2015 Seattle Building Code, Chapter 24, Section 2405 Sloped glazing and skylights (IBC text as adopted)
- VELUX Commercial UK — Laminated inner panes in glazed rooflights (9 March 2026)
- VELUX Commercial — Understanding skylight energy performance: U-value, g-value and energy balance (2 January 2025)
- Vitro Architectural Glass — Managing thermal stress breakage
- The Construction Specifier — Rooftop skylight replacement considerations, part 1: investigation and AAMA 511 forensic water testing (5 March 2022)
- The Construction Specifier — Rooftop skylight replacement considerations, part 3: roof tie-in and drainage (5 March 2022)
- The Construction Specifier — Rooftop skylight replacement considerations, part 4: condensation (5 March 2022)
- Natural Resources Canada — Condensation on windows, doors and skylights
- Roofglaze — Skyway fixed flat glass rooflight installation guide (January 2022)
- Sunsquare via Barbour Product Search — Installing flat roof skylights: minimum pitch (21 September 2017)
- Pilkington — Pilkington Activ self-cleaning glass, technical FAQs
- Said & Walwil (KFUPM) — Fundamental studies on dust fouling effects on PV module performance, Solar Energy 107 (2014)
- pv magazine — Best tilt angle to improve PV module performance in the world's worst soiling zone (20 January 2025)
- Abdou et al. — Aligning national building codes with energy rating systems for sustainable residential development (2026, SBC 602 homes)